![FS040 Pf-Ri plus](/sites/default/files/styles/produktbild/public/produkt/img_serie_fs040_pf-ri_plus.png?itok=ww4gklpt)
HUECK Trigon FS 040
Mullion/transom or transom/transom design, 40 mm elevation width
Resistance to wind (DIN EN 12 179)
Permitted load = 2.4 kN/m² / Increased load = 3.6 kN/m²
Water tightness (DIN EN 12 154)
Up to class RE1200
Determining airborne sound insulation at the test bench (DIN EN ISO 10140-2)
48 dB
Thermal transmittance (EN ISO 10077-2)
Uf ≥ 1.09 W/m²K
Air permeability (DIN EN 12 152)
Up to class AE (>600 Pa)
Burglar resistance (EN 1627)
RC 1 N, RC 2, RC 2 N
Fall protection (DIN 18 008-4)
Guaranteed by standard façade screws
![HUECK Trigon FS 050 Pf-Ri plus](/sites/default/files/styles/produktbild/public/produkt/img_serie_fs050_pf-ri_plus.png?itok=hyjWphJf)
HUECK Trigon FS 050
Mullion/transom or transom/transom design, 50 mm elevation width
Resistance to wind (DIN EN 12 179)
Permitted load = 2.4 kN/m² / Increased load = 3.6 kN/m²
Water tightness (DIN EN 12 154)
Up to class RE1200
Determining airborne sound insulation at the test bench (DIN EN ISO 10140-2)
48 dB
Thermal transmittance (EN ISO 10077-2)
Uf ≥ 0.69 W/m²K
Air permeability (DIN EN 12 152)
Up to class AE (>600 Pa)
Burglar resistance (EN 1627)
RC 1 N, RC 2, RC 2 N, RC 3
Fall protection (DIN 18 008-4)
Guaranteed by standard façade screws
![HUECK Trigon FS 050 SG](/sites/default/files/styles/produktbild/public/produkt/img_serie_fs050sg.png?itok=YfjBmOTK)
HUECK Trigon FS 050 SG
Mullion/transom or transom/transom design, 50 mm elevation width
Resistance to wind (DIN EN 12 179)
Permitted load = 2.4 kN/m² / Increased load = 3.6 kN/m²
Water tightness (DIN EN 12 154)
Up to class RE750
Determining airborne sound insulation at the test bench (DIN EN ISO 10140-2)
45 dB
Thermal transmittance (EN ISO 10077-2)
Uf ≥ 0.81 W/m²K
Air permeability (DIN EN 12 152)
Up to class AE (>600 Pa)
Burglar resistance (EN 1627)
RC 1 N, RC 2, RC 2 N, RC 3
Fall protection (DIN 18 008-4)
Guaranteed by standard façade screws and toggles
![HUECK Trigon FS 060 Pf-Ri plus](/sites/default/files/styles/produktbild/public/produkt/img_serie_fs060_pf-ri_plus.png?itok=6eYu7Yvs)
HUECK Trigon FS 060
Mullion/transom or transom/transom design, 60 mm elevation width
Resistance to wind (DIN EN 12 179)
Permitted load = 2.4 kN/m² / Increased load = 3.6 kN/m²
Water tightness (DIN EN 12 154)
Up to class RE1200
Determining airborne sound insulation at the test bench (DIN EN ISO 10140-2)
48 dB
Thermal transmittance (EN ISO 10077-2)
Uf ≥ 0.65 W/m²K
Air permeability (DIN EN 12 152)
Up to class AE (>600 Pa)
Burglar resistance (EN 1627)
RC 1 N, RC 2, RC 2 N, RC 3
Fall protection (DIN 18 008-4)
Guaranteed by standard façade screws
![HUECK Trigon FS 060 SG](/sites/default/files/styles/produktbild/public/produkt/img_serie_fs060sg.png?itok=4q7wgImv)
HUECK Trigon FS 060 SG
Mullion/transom or transom/transom design, 60 mm elevation width
Resistance to wind (DIN EN 12 179)
Permitted load = 2.4 kN/m² / Increased load = 3.6 kN/m²
Water tightness (DIN EN 12 154)
Up to class RE750
Determining airborne sound insulation at the test bench (DIN EN ISO 10140-2)
45 dB
Thermal transmittance (EN ISO 10077-2)
Uf ≥ 0.76 W/m²K
Air permeability (DIN EN 12 152)
Up to class AE (>600 Pa)
Burglar resistance (EN 1627)
RC 1 N, RC 2, RC 2 N, RC 3
Fall protection (DIN 18 008-4)
Guaranteed by standard façade screws and toggles